CLJBS - TYPE II WALKWAY DARK GULL GRAY, G-8130

  • MSDS: CLJBS
  • Manufacturer: AKRON PAINT AND VARNISH INC
  • Product Name: TYPE II WALKWAY DARK GULL GRAY, G-8130
  • National Stock Number: 8010-00-641-0426
Product Identification

Product ID:TYPE II WALKWAY DARK GULL GRAY, G-8130
MSDS Date:01/26/2000
FSC:8010
NIIN:00-641-0426
Status Code:A
MSDS Number: CLJBS

Responsible Party
AKRON PAINT AND VARNISH INC
1390 FIRESTONE PARKWAY
AKRON, OH 44301-1624
US

Emergency Phone: (800)424-9300

Info Phone: 216-773-8911

Preparer: HENRY SIMMONS

Cage: 70228

Contractor
AKRON PAINT AND VARNISH INC
AKRON, OH 44301-1624 US

Telephone: 216-773-8911

Cage: 70228

Ingredients

V M & P NAPHTHA

CAS: 64742-89-8

OSHA PEL 300 PPM

ACGIH TLV: 300 PPM


CRYSTALLINE SILICA

ACGIH TLV: 0.10 MG/M3


XYLENE

CAS: 1330-20-7

RTECS: ZE2100000

OSHA PEL 100 PPM

ACGIH TLV: 434 MG/M3;100 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Effects of Overexposure:EYES: CAN CAUSE REDNESS, IRRITATION, SWELLING
AND BLURRED VISION. SKIN: PROLONGED OR
REPEATED CONTACT CAN CAUSE MODERATE IRRITATION, DEFATTING, DERMATITIS.
BREATHING:EXCESSIVE INHALATION OF VAPORS AND/OR SPRAY MIST CAN
CAUSE RESPIRATORY, DIZZINESS,
WEAKNESS, FATIGUE, NAUSEA, HEADACHE, UNCONSCIOUSNESS AND EVEN
ASPHYXIATION.
SWALLOWING: CAN CAUSE GASTROINTESTINAL IRRITATION, NAUSEA, VOMITING AND
DIARRHEA;
ASPIRATION OF MATERIAL INTO THE LUNGS CAN CAUSE CHEMICAL PNEUMONITIS
WHICH CAN BE
FATAL.

First Aid

First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER FOR 15 MINUTES. LIFT
EYELIDS OCCASIONALLY,
GET PROMPT MEDICAL ATTENTION. SKIN: WASH THOROUGHLY WITH SOAP AND
WATER, REMOVE
CONTAMINATED CLOTHING PROMPTLY; WASH CLOTHING BEFORE REUSE. CONSULT A
PHYSICIAN IF
IRRITATION PERSISTS. SWALLOWING: SINCE THIS PRODUCT MAY CONTAIN
MATERIALS WHICH CAN
CAUSE LUNG DAMAGE IF ASPIRATED INTO THE LUNGS, THE DECISION WHETHER TO
INDUCE
VOMITING MUST BE MADE BY A PHYSICIAN AFTER CAREFUL CONSIDERATION OF ALL
MATERIALS
INGESTED. INHALATION: MOVE AFFECTED PERSON TO FRESH AIR. IF BREATHING
IS DIFFICULT,
ADMINISTER OXYGEN.

Fire Fighting

Flash Point Method:SCC
Flash Point:=10.C, 50.F
Lower Limits:0.9%
Upper Limits:7%
Extinguishing Media:CARBON DIOXIDE- DRY CHEMICAL ? FOAM ? WATER FOG
Fire Fighting Procedures:USE SELF ?CONTAINED BREATHING APPARATUS WITH A
FULL FACEPIECE OPERATED IN PRESSURE-DEMAND OR OTHER POSITIVE
PRESSURE MODE. WEAR PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR AND MAY
TRAVEL ALONG THE GROUND TO AN IGNITION SOURCE SOME DISTANCE FROM
MATERIAL HANDLING POINT. IGNITION SOURCES INCLUDE PILOT LIGHTS,
SMOKING, HEATERS, ELECTRIC MOTORS, SPARKS FROM ELECTRICAL SWITCHES
AND STATIC DISCHARGES.

Accidental Release

Spill Release Procedures:SMALL SPILL: ABSORB LIQUID WITH RAGS, FLOOR
ABSORBENT, VERMICULITE OR OTHER
ABSORBENT MATERIAL AND TRANSFER TO HOOD. LARGE SPILL: ELIMINATE AL
IGNITION SOURCES -
DIKE ARE OF SPILL TO PREVENT SPREADING ? VENTILATE AREA IF INDOORS -
PUMP LIQUID INTO
SALVAGE TANKS ? REMAINING LIQUID MAY BE TAKEN UP WITH SAND, FLOOR
ABSORBENT OR
OTHER ABSORBENT MATERIAL AND SHOVELED INTO CONTAINERS.

Handling

Handling and Storage Precautions:DO NOT DROP CONTAINERS. AVOID HEAT,
SPARKS, AND OPEN FLAMES. STORE LARGE QUANTITIES
ONLY IN BUILDINGS DESIGNED TO COMPLY WITH OSHA 1910.106. NEVER USE
PRESSURE TO EMPTY.
AVOID BREATHING WITH SANDING D UST. DO NOT HANDLE UNTIL THE
MANUFACTURERS SAFETY
PRECAUTIONS HAVE BEEN READ AND UNDERSTOOD.

Exposure Controls

Respiratory Protection:IN OUTDOOR OR OPEN AREAS WITH UNRESTRICTED
VENTILATION APPROVED CHEMICAL FILTERS DESIGNED TO REMOVE A
COMBINATION OF PARTICULATES AND VAPOR.
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP AIR CONTAMINANT CONCENTRATION BELOW CURRENT APPLICABLE OSHA
PERMISSIBLE EXPLOSIVE LIMIT
Protective Gloves:WEAR RESISTANT GLOVES SUCH AS: NITRILE RUBBER.
Eye Protection:CHEMICAL SPLASH GOGGLES IN COMPLIANCE WITH OSHA
REGULATIONS ARE ADVISED.
Other Protective Equipment:NORMAL PROTECTIVE CLOTHING. WASH
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:>115.6C, 240.F
B.P. Text:240-285F, 115.56-140.5
Vapor Density:>AIR
Spec Gravity:1.318
VOC Grams/Liter:3.35
Appearance and Odor:GRAY LIQUID
Percent Volatiles by Volume:30.56%

Stability

AVOID CONTACT WITH STRONG OXIDIZERS (E.G. NITRIC ACID)
Stability Condition to Avoid:KEEP AWAY FROM HEAT AND OPEN FLAMES.
Hazardous Decomposition Products:MAY FORM CARBON MONOXIDE AND DIOXIDE,
VARIOUS HYDROCARBONS, ETC

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE,
AND LOCAL REGULATIONS

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Regulatory

SARA Title III Information:SECTION 313: THIS REPORTING CONTAINS THE
FOLLOWING TOXIC CHEMICALS SUBJECT TO THE REPORTING REQUIREMENTS OF
SECTION 313 OF THE EMERGENCY PLANNING AND COMMUNITY RIGHT TO KNOW
ACT OF 1986 AND 40 CFR 372 : XYLENE 1330-20-7 1.19%
State Regulatory Information: